Follicle-Puncture-System Bielefeld I-III
Product Description:
The follicle puncture set "Bielefeld" is a simple system without flushing
device. It has a silicone stopper for 14 ml round bottom tubes (BD
Falcon). The system tubes are of polyethylene. The system is available
with aspiration needles with outer diameters of 1.4 mm and 1.6 mm
and etched or milled ultrasound reflective marks. For orders please
mention extra. The follicle puncture set "Bielefeld" can also be delivered
with stoppers for 26 ml tubes (Sarstedt). On request we also compose
follicle puncture sets according to your individual wishes (minimum
order 50 pieces).
Technical Data:
· no flushing device
· outer diameter of the needle 1.4 mm or 1.6 mm
· needle length 32 cm
· silicone stopper for BD Falcon 2001 tubes
· product of class 2 b
· tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
Bielefeld I US-marks milled, Ø out 1.4 mm; Article No. 461230
Stck.
Bielefeld II US-marks etched, Ø out 1.4 mm; Article No. 461231
Stck.
Bielefeld III US-marks etched, Ø out 1.6 mm; Article No. 661231
|
 |
Follicle-Puncture-System Tübingen I-III
Product Description:
The follicle puncture system "Tübingen" is equipped with a three-way
stopcock at the silicone stopper (fits to 14 ml round bottom tubes,
BD Falcon) and allows the flushing of the follicles by the assisting
co-worker. The tubes are of polyethylene. The system is available
with aspiration needles with outer diameters of 1.4 mm and 1.6 mm
and with etched or milled ultrasound reflective marks. The follicle
puncture set "Tübingen" can also be delivered with stoppers for 26
ml tubes (Sarstedt). For orders please mention extra. On request we
also compose follicle puncture sets according to your individual wishes
(minimum order 50 pieces).
Technical Data:
· System with three-way stopcock for follicle flushing
· outer diameter of the needle 1.4 mm or 1.6 mm
· needle length 32 cm
· silicone stopper for BD Falcon 2001 tubes
· product of class 2 b
· tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
Tübingen I US-marks milled, Ø out 1.4 mm; Article No. 481232
Stck.
Tübingen II US-marks etched, Ø out 1.4 mm; Article No. 481233
Stck.
Tübingen III US-marks etched, Ø out 1.6 mm; Article No. 671233
|
 |
Follicle-Puncture-System
Bonn I - III
Product
Description:
The follicle puncture set "Bonn" is equipped with two three-way
stopcocks and allows the assisting co-worker as well as the doctor
to flush the follicles. It has a silicone stopper for 14 ml round
bottom tubes (BD Falcon). The system tubes are of polyethylene. The
system is available with aspiration needles with outer diameters of
1.4 mm and 1.6 mm and etched or milled ultrasound reflective marks.
The follicle puncture set "Bonn" can also be delivered with stoppers
for 26 ml tubes (Sarstedt). For orders please mention extra. On request
we also compose follicle puncture sets according to your individual
wishes (minimum order 50 pieces).
Technical Data:
· two three-way stopcocks for follicle flushing
· outer diameter of the needle 1.4 or 1.6 mm
· needle length 32 cm
· silicone stopper for BD-Falcon 2001 tubes
· product of class 2 b · tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
Bonn I US-marks milled, Ø out 1.4 mm; Article No. 481236
Stck.
Bonn II US-marks etched, Ø out 1.4 mm; Article No. 481237
Stck.
Bonn III US-marks etched, Ø out 1.6 mm; Article No. 681237
|
 |
Follicle-Puncture-System Mülheim I-III
Product Description:
The follicle puncture set "Mülheim" is equipped with a three-way
connector that allows via its lateral female Luer-connector the flushing
of the follicles using a syringe or a tube. The tubes of the system
are of polyethylene and it has a silicone stopper for 14 ml round
bottom tubes (BD Falcon). The system is available with aspiration
needles with outer diameters of 1.4 mm and 1.6 mm and etched or milled
ultrasound reflective marks. The follicle puncture set "Bielefeld"
can also be delivered with stoppers for 26 ml tubes (Sarstedt). For
orders please mention extra. On request we also compose follicle puncture
sets according to your individual wishes (minimum order 50 pieces).
Technical Data:
· three-way stopcock for follicle flushing
· outer diamater of the needle 1.4 or 1.6 mm
· needle length 32 cm
· silicone stopper for BD-Falcon 2001 tubes
· product of class 2 b
· tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
Mülheim I US-marks milled, Ø out 1.4 mm; Article No. 471230
Stck.
Mülheim II US-marks etched, Ø out 1.4 mm; Article No. 471231
Stck.
Mülheim III US-marks etched, Ø out 1.6 mm; Article No. 671231
|
 |
Follicle-Puncture-System T-Standard I-III
Product Description:
The follicle puncture system "T-Standard" is composed for the
use with automatic flushing devices. The flushing tube has a male
Luer-connector that fits for example to the flushing apparatus of
Labotect. The system tubes are of polyethylene. The system is available
with aspiration needles with outer diameters of 1.4 mm and 1.6 mm
and etched or milled ultrasound reflective marks. On request we also
compose follicle puncture sets according to your individual wishes
(minimum order 50 pieces).
Technical Data:
· three-way system with connector for automatic flushing devices
· outer diameter of the needle 1.4 mm or 1.6 mm
· needle length 32 cm
· silicone stopper for BD-Falcon 2001 tubes
· product of class 2 b
· tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
T-Standard I US-marks milled, Ø out 1.4 mm; Article No. 491230
Stck.
T-Standard II US-marks etched, Ø out 1.4 mm; Article No. 491231
Stck.
T-Standard III US-marks etched, Ø out 1.6 mm; Article No. 691230
|
 |
Follicle-Puncture-System T-Standard double
lumen I-II
Product Description:
The double lumen needle of the follicle puncture system "T-Standard
double lumen" allows to flush follicles while they are aspirated.
The flushing tube is available with a male (for the use with automatic
flushing devices, e. g. Labotect) or a female Luer-connector (for
the connection or syringes or tubes). The system tubes are of polyethylene.
The aspiration needle has an outer diameter of 1.6 mm and an etched
ultrasound mark. On request we also compose follicle puncture sets
according to your individual wishes (minimum order 50 pieces).
Technical Data:
· double lumen system with connector for automatic flushing device
or syringe/tube
· outer diameter of the needle 1.6 mm
· needle length 32 cm
· product of class 2 b
· tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
T-Standard double lumen flushing connector Luer female; Article No.
891230
Stck.
T-Standard double lumen flushing connector Luer male; Article No.
891231
|
 |
Follicle-Puncture-System T-Plus I-III
Product Description:
The follicle puncture system "T-Plus" is composed for the use with
automatic flushing devices. The flushing tube has a male Luer-connector
that fits for example to the flushing apparatus of Labotect. The system
has a silicone stopper for 14 ml round bottom tubes (BD Falcon). The
system tubes are of polyethylene. The set is available with aspiration
needles with outer diameters of 1.4 mm and 1.6 mm and etched or milled
ultrasound reflective marks. The follicle puncture set "T-Plus" can
also be deliverd with stoppers for 26 ml tubes (Sarstedt). For orders
please mention extra. On request we also compose follicle puncture
sets according to your individual wishes (minimum order 50 pieces).
Technical Data:
· three-way system with connector for automatic flushing devices
· outer diameter of the needle 1.4 mm or 1.6 mm
· needle length 32 cm
· silicone stopper for BD-Falcon 2001 tubes
· product of class 2 b
· tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
T-Plus I US-marks milled, Ø out 1.4 mm; Article No. 491232
Stck.
T-Plus II US-marks etched, Ø out 1.4 mm; Article No. 491233
Stck.
T-Plus III US-marks etched, Ø out 1.6 mm; Article No. 691233
|
 |
Follicle-Puncture-System T-Plus double
lumen I-III
Product Description:
The double lumen needle of the follicle puncture system "T-Plus double
lumen" allows to flush follicles while they are aspirated. The flushing
tube is available with a male (for the use with automatic flushing
devices, e. g. Labotect) or a female Luer-connector (for the connection
or syringes or tubes). The system has a silicone stopper for 14 ml
round bottom tubes (BD Falcon). The system tubes are of polyethylene.
The aspiration needle has an outer diameter of 1.6 mm and an etched
ultrasound mark. The follicle puncture set "T-plus double lumen" can
also be delivered with stoppers for 26 ml tubes (Sarstedt). For orders
please mention extra. On request we also compose follicle puncture
sets according to your individual wishes (minimum order 50 pieces).
Technical Data:
· double lumen system with connector for automatic flushing device
or syringe/tube
· outer diameter of the needle 1.6 mm
· needle length 32 cm
· silicone stopper for BD Falcon 2001 tubes
· product of class 2 b
· tested for embryo toxicity
· sterilized by g-radiation
· individually packed
· sales unit: 15 pieces
Stck.
T-Plus double lumen flushing connector Luer female; Article No. 891232
Stck.
T-Plus double lumen flushing connector Luer male; Article No. 891233
|